# Architecture — and where your data plugs in
The one-pager for the engineer who asks *"can it take our data?"*
## Shape
```
┌──────────────────── telemetry sources ─────────────────────┐
│ │
│ SimulatedSource MqttSource OpcUaSource │
│ (working) (stub) (stub) │
│ │ │ │ │
└────────┴────────────────────┴───────────────────┴──────────┘
│
TelemetrySource ← the seam
emits "frames"
│
┌───────────────┴────────────────┐
│ │
AnalyticsEngine WebSocket /ws ──► React dashboard
· threshold alarms │ · 3D scene
· learned baselines / z-scores │ · trend charts
· least-squares trend projection │ · alarms
· alarm latching │ · what-if controls
│ │
└──────────► frame.analytics ─────┘
│
Copilot ──► OpenRouter / Ollama / rule engine
(context = analytics conclusions, not raw floats)
```
Everything above the seam consumes **frames** and has no idea where they came
from. That is the whole design: swapping the simulator for your plant means
implementing one class.
## The seam
`server/ingest/source.js` defines `TelemetrySource`. A source does three things:
1. **`start()`** — connect, subscribe, begin producing.
2. **`emit(frame)`** — hand a frame upward. Called on your cadence.
3. **`capabilities`** — declare what it supports (`timeControl`,
`faultInjection`, `setpointControl`). The UI reads this and hides controls a
read-only source cannot honour, rather than showing buttons that do nothing.
A frame is station states, signal values, WIP levels, KPI rollups and the
analytics block. `server/ingest/simulatedSource.js` is the reference
implementation; read it alongside the stub you are filling in.
## Connecting your plant
Both adapters are written out as documented stubs with the real interface, the tag
map, and the traps called out. They throw an honest "not configured" error rather
than pretending to work.
### MQTT — `server/ingest/mqttSource.js`
```
npm i mqtt
```
Fill `TAG_MAP` with your topics, implement `start()`, set `TELEMETRY_SOURCE=mqtt`
and `MQTT_URL`. If your broker speaks **Sparkplug B** (most industrial ones do),
add `sparkplug-payload` and map metric aliases from NBIRTH/NDATA instead of topic
strings.
### OPC-UA — `server/ingest/opcuaSource.js`
```
npm i node-opcua
```
Browse your server's address space, fill `NODE_MAP` with real NodeIds (never guess
them — they are namespace-qualified and installation-specific), implement
`start()`, set `TELEMETRY_SOURCE=opcua` and `OPCUA_ENDPOINT`.
### Historian / CSV
Simplest of the three and often the best first step: read the export, sort by
timestamp, and emit frames on a timer with a scrub control. You get real customer
data in the twin without touching plant networks or waiting on IT.
## Four things that bite when the data is real
These are called out in the stubs too, because each one is a way a twin starts
lying:
**Staleness.** Track last-seen per tag and mark a station offline when its tags go
quiet. A stale value rendered as live is worse than a gap. The demo already models
this — the `INS-04 sensor dropout` fault holds the last value and flags the
station rather than drawing zeros, and the charts stop rather than continuing a
flat line that would read as a healthy steady state.
**Status codes.** OPC-UA gives you `StatusCode` per value. A Bad or Uncertain
reading must not become a data point.
**Timestamps.** Prefer the *source* timestamp — when the PLC sampled the sensor —
over the server timestamp, which is when the message reached you. Under load they
diverge, and trend slopes computed on arrival times are wrong.
**Units.** Vibration in in/s, temperature in °F, pressure in psi are all common.
Convert at the boundary, never downstream, or every threshold in the system is
quietly wrong.
## What the analytics layer needs from you
Nothing changes. `TrendTracker` and `BaselineBank` work on timestamped values
regardless of origin. Two things worth knowing:
- **Baselines are learned then frozen.** A continuously adapting baseline absorbs
a slow ramp, so the exact failure mode this is built to catch would never raise
a z-score. Freezing means "different from how this machine normally behaves".
- **Signals declare their own analytics eligibility.** In
`server/sim/stations.js`, `cumulative: true` (tool wear, part counters) and
`volatile: true` (belt speed, setpoints) exclude a signal from anomaly testing —
normal accumulation is not an anomaly, and normal state swings are not either.
Both remain covered by thresholds and trend projection. When you add your
signals, set these flags next to the definition.
## Writing back to the plant
`OpcUaSource` is read-only on purpose, and its `capabilities` say so. OPC-UA can
write to a PLC, and a twin that closes the loop is genuinely valuable — but it
needs interlocks, an audit trail, rate limits and the customer's explicit
sign-off. Do not enable it because the demo UI has a slider.
## Deployment
One Node process plus a static bundle:
```
npm run build # web/dist
node server/index.js # serves the API and the telemetry socket
```
Runs on a plant-floor box or an industrial PC. With Ollama or the rule-based
copilot it needs no internet at all — which for most plant networks is not a
preference but a requirement.
## Honest limits of the demo
Worth saying out loud, because the engineer will work it out anyway:
- The physics is first-order lags, a PID and accumulating wear — enough that
signals move the way an engineer expects and stay coupled. It is not FEA or CFD,
and it is not calibrated against a real machine.
- The five stations are a plausible generic line, not the customer's process.
- Prediction is trend extrapolation. There is no trained model and no failure
history behind it. With real historical failure data you could do considerably
better — and that is the natural next conversation, not a gap to hide.